H03VV-F, 50525-2-11
CONSTRUCTION
Conductor
Fine-stranded copper (Class 5)
Insulation
Polyvinyl chloride
Outer sheath
Polyvinyl chloride
SPECIFICATIONS
Max. short circuit temperature
Max. operating temperature
Min. bending radius
If D<8 then 4xD
If 8<D<12 then 5xD
If D>12 then 6xD
If 8<D<12 then 5xD
If D>12 then 6xD
Flame propagition test on single cable
EN 60332-1
AC test voltage
Rated voltage Uo/U
ROHS & REACH compliant
Lead free
APPLICATIONS
Used as connection cables, in dry and humid places that there are not much mechanical compulsion which are generally used in household equipments.
TECHNICAL DATA ( CU/PVC/PVC )
Nomnal Cross Secton mm2
|
Overall Dameter mm approxmately
|
Net Weght kg/km approxmately |
Conductor DC Resstance at (20°C) max. ohm/km
|
Current Carryng Capacty In
|
|
---|---|---|---|---|---|
Air (A) | |||||
H03VV-F, 50525-2-11 | |||||
2x0,50 | 5,0 | 36 | 39,0 | 3 | |
2x0,75 | 5,5 | 46 | 26,0 | 6 | |
3x0,50 | 5,3 | 43 | 39,0 | 3 | |
3x0,75 | 5,8 | 43 | 26,0 | 6 | |
4x0,50 | 5,8 | 54 | 39,0 | 3 | |
4x0,75 | 6,4 | 53 | 26,0 | 6 |