Skip links

NYIFY-F (300/500 V)

NYIFY-F

Pvc Insulated, Pvc Sheathed, Flexible Flat Cables

VDE 0250

CONSTRUCTION

Conductor

İnce çok telli bakır
Fine-stranded copper (Class 5)

Insulation

Polyvinyl chloride

Outer Sheath

PVC
Polyvinyl chloride

SPECIFICATIONS

Max. short circuit temperature
Max. operating temperature
Min. bükülme yarı çapı
Min. bending radius
If D<8 then 4xD
If 8<D<12 then 5xD
If D>12 then 6xD
Tek kablo düşey alev yayılma testi
Flame propagition test on single cable
EN 60332-1
2-kv
AC test voltage
300/500-v
Rated voltage Uo/U
ROHS & REACH compliant
Lead free

APPLICATIONS

Uygulama alanları

Suitable for dry and humid areas. All type of factory, warehouse and depots where there is fire and explosion threat. Not suitable for underground. Used in fixed installations laying in conduit on and under plaster.

TECHNICAL DATA ( Cu/PVC/PVC )

Nominal Cross Section mm² Overall Diameter mm approximately Net Weight kg/km approximately Conductor DC Resistance at (20°C) max. ohm/km Current Carrying Capacity in
Air (A)
NYIFY-F (300/500 V)
2x1 4.0 x 9.3 56 19.5 13
2x1.5 4.4 x 10.6 77 13.3 16
2x2.5 5.0 x 12.0 106 7.98 21
2x4 5.6 x 14.1 142 4.95 27
3x1 4.0 x 14.9 84 19.5 13
3x1.5 4.9 x 17.6 108 13.3 16
3x2.5 5.0 x 19.6 148 7.98 21
3x4 5.6 x 23.1 199 4.95 27